GASMONITOR SYSTEM GASMASTER DETECTOR-FLAMGARD
GAS DETECTOR - Tx GARD CSM 500G (Portable) CSM200 (Portable)
GASMAN II Series CUSTODIAN

¥°. Features
16¡¿2 Alpha-Numeric LCD module with LED backlight
Display operating time and battery status(%)
HIGH, LOW, STEL, TWA, PEAK Alarm
Audio and visual alarms and earphone for noisy environment
Auto calibration, Auto zero by key operation
Approval Code : Ex ib ¥±B T4
¥±. Specifications
STEL
TWA
Short Term Exposure Limit
Time Weighted Average
¥². Applications
* Manhole * Chemical plants * Tunnels
* Silos * Storage Tank  
Display
16¡¿2 Alpha-Numeric : LCD Module
Power Source
1.2V¡¿4EA rechargeable, 9V 850mA adaptor (110/220V)
Operating time
Over 16 hrs continuous use after 3 hrs high speed charged
Dimensions
143(D) ¡¿ 88(W) ¡¿ 46(H)
Weight
357g (without battery)
¥². Specification
Oxygen
Carbon monoxide
Hydrogen sulfide
Combustible
Detection principle
Electrochemical
Catalytic combustion
Measuring - range
Normal
0¡­25%
0¡­500ppm
0¡­100ppm
0¡­100%LEL
Max
0¡­30%
0¡­1500ppm
0¡­500ppm
0¡­100%LEL
Resolution
0.1%
1ppm
0.1ppm
0.1%LEL
Alarm type
HI, LOW, PEAK
HI, STEL, TWA, PEAK
HI, PEAK
Sensor lifetime
2 years