GASMONITOR SYSTEM GASMASTER DETECTOR-FLAMGARD
GAS DETECTOR - Tx GARD CSM 500G (Portable) CSM200 (Portable)
GASMAN II Series CUSTODIAN

  ¥°. Applications
Manhole, Chemical plant, Tunnels, Silos, Sewers, Storage tank.

¥±. Features
- 16x2 alpha-numeric LCD module with LED backit
- Display operating time and battery staus (%)
- High, Low, STEL, TWA, Peak Alarm
- Audio and visual alarms and earphone for noisy
    environment.
- 3 hours high speed charge and 16 hrs continuos use
- Auto calibration, Auto zero by key operation
- Approval code : Ex ib llB T6
¥². Specifications
MODEL
TRIPLE PLUS
Measurement
O2, CO, H2S, Flammable. Option : Cl2, NO, SO2, NH3 ¡¦
Measuring Range
O2 ; 0 ¡­ 25% CO ; 0 ¡­ 1000ppm,
H2S : 0 ¡­ 50ppm Flammable ; 0 ¡­ 100%LEL
Display
16¡¿2 Alpha-numeric LCD Module
Power
6.0VDC Rechargeable battery pack, 110/220VAC Adaptor
Dimension
167(D) ¡¿ 118(W) ¡¿ 73(H)
  WEIGHT
  750g (without accessories)
  OPTIONS
  Data Logger, Pump, Cl2, NO, NO2, SO2, NH3 ¡¦ sensors