¥°. ±â±â°³¿ä
|
- 1732ºÐ¼®±â °¡¿ ¶Ç´Â ºñ°¡¿ Áö¸£ÄÚ´Ï¾Æ ¼¾¼¸¦ ¼±ÅÃÇÏ¿© »ç¿ë °¡´ÉÇÏ´Ù. ÀÌ ºÐ¼®±â´Â "NERNST" °ø½Ä¿¡ ¸ÂÃá °ÍÀÌ´Ù. ¾î¶² Á¾·ùÀÇ ºÐ¼®±â´Â 900¡ÉÀÇ ÇѰèÁ¡ÀÌ ÀÖÁö¸¸ 1732 ºÐ¼®±â´Â 1400¡É ±îÁö ¿¡¼ Á¤È®ÇÑ »ê¼Ò, ÀÌ»êÈź¼Ò, È¿À², ¿Âµµ ÃøÁ¤Ä¡¸¦ Á¦°øÇÑ´Ù. |
¥±. Ư ¡
- Automatic Calibration ±â´É
- Auto Purge ±â´É
- Output ±³Á¤±â´É(90¡00%,KeySetting)
- Damping ±â´ÉÀ¸·Î Noise¿¡ °ÇÏ´Ù.
- ÃøÁ¤ Ç׸ñÀÌ ¸¹À¸¹Ç·Î ¿©·¯ °¡Áö Á¤º¸¸¦ ¾òÀ» ¼ö ÀÖ´Ù.
- Zirconia Sensor´Â Zirconia tipÀ» Alumina Tube¿¡ BondingÇÏ¿© Á¤µµ°¡ ÁÁ°í ¼ö¸íÀÌ ±æ´Ù. (±¹Á¦Æ¯Çã ȹµæ)
- °æº¸(sensor fail, heater fail, TC open, ref fail, ADC cal fail, DAC cal fail, cal gas fail, O©ü high, probe tem µî)
±â´ÉÀ¸·Î ºÐ¼®±â±âÀÇ Á¤µµ ¹× »çÈİü¸®°¡ ¿ëÀÌÇÏ´Ù.
- 1,000°³ÀÇ ¾Ë¶÷±â·Ï °¡´É
(¾Ë¶÷ÀÇ ¹ß»ý½Ã°£, ½ÂÀνð£,
Á¦°Å½Ã°£ ÀúÀå)
- ´õ¿í Ä¿Áø DISPLAY
(ºÐ¼®±â »óÅ ±âÈ£·Î Ç¥½Ã,
Ä¿Áø O2°ª Ç¥½Ã±â´É)
- °£´ÜÇØÁø ¸Þ´º±¸¼º(USER¿¡ ¸Â°Ô ±¸¼º °¡´É)
- IP65 : ¹æÁø¹æ½À ±â´É |
|
|
 |
|
Ãø Á¤ Ç× ¸ñ
|
O©ü,CO©ü,Probe EMF, Probe Temp, ¹è±â°¡½º¿Âµµ, ¿¬¼ÒÈ¿À² ½Ã°£
³¯Â¥, °úÀ×°ø±âÀ², ¼ºñ½º³¯Â¥, Probe Impedance, CO/CO©ü
|
|
Ãø Á¤ ¹ü À§
|
O2 : 0¢¦100% or 1x10-30ppm Oxygen(ÀÚµ¿ º¯È¯)
CO©ü: 0¡40% O2 °áÇÌ : -10¢¦20%
Probe EMF: 0¡1300mv
¹è±â°¡½º¿Âµµ: 0¡1600¡É (K, R, S, N, J Type ¼±Åð¡´É)
½Ç³»¿Âµµ : 0¡70¡É
¿¬¼ÒÈ¿À² : 0¡100%, Combustible : 0¡2.0%
Probe Impedance : 0¢¦300k |
|
Ãø Á¤ Á¤ µµ
|
¡¾0.5% of measures value |
|
ÃøÁ¤ Sensor ¹æ¹ý
|
O©ü: Zirconia Type (ZrO©ü), Temp : K, R, S, N, J Type ¼±ÅÃ
±âŸ : Calculated |
|
Ãâ ·Â
|
4¡20mA,
1¡5 VDC Dual Channel
RS 232C, RS 485 |
|
¿Ü Çü Å© ±â
|
Transmitter : 260(W)¡¿160(H)¡¿90(D)
O©ü Probe : NPS 1*¨ö" or Flange (Ordered)
Length : 250mm, 300mm, 350mm, 500mm, 750mm, 1000mm |
|
»ç ¿ë Àü ¿ø
|
85~265VAC(free volt), 50/60Hz |
|
|